Comparison of three echo-guidance techniques in percutaneous patent foramen ovale closure for stroke prevention

Conventional transoesophageal, microprobe transoesophageal and intracardiac echocardiography

La Grande Journée du Coeur (13 juin 2023)
Attention : plus que quelques places restantes !

La Grande Journée du Coeur (mardi 13 juin 2023)
Les présentations sont en ligne

Colloquium "Rythme et conduction" (23 avril 2024)
Inscrivez-vous !

Archives of Cardiovascular Diseases 2023 Nov;116(11):523-528
Article disponible en consultant le site

Auteurs

Reibel I, Hauguel-Moreau M, Guedeney P, Hage G, Hammoudi N, Duthoit G, Zeitouni M, Lattuca B, Kernéis M, Collet JP, Silvain J, Montalescot G; ACTION Study Group.

Abstract

Background

Recent randomized trials have demonstrated a consistent reduction in recurrent stroke after percutaneous transcatheter patent foramen ovale closure versus medical therapy in patients with recent cryptogenic stroke.

Aims

To compare the safety and efficacy of intracardiac echocardiography-guided and microprobe transoesophageal echocardiography-guided patent foramen ovale closure under local anaesthesia with transoesophageal echocardiography-guided patent foramen ovale closure under general anaesthesia.

Methods

This prospective observational single-centre study included 194 consecutive patients scheduled for patent foramen ovale closure for secondary prevention of stroke from February 2018 to December 2019. Patients were asked to choose between an intracardiac echocardiography-guided, microprobe transoesophageal echocardiography-guided or transoesophageal echocardiography-guided procedure. The primary endpoint was the rate of successful closure at 6 months, defined as correct positioning of the device without severe shunt on 6-month contrast echocardiography.

Results

Successful closure was high and did not differ between groups: 97.8% (95% confidence interval 88.5–99.9%) in the intracardiac echocardiography-guided group versus 96.9% (95% confidence interval 83.8–99.9%) in the microprobe transoesophageal echocardiography-guided group and 99.1% (95% confidence interval 95.3–99.9%) in the transoesophageal echocardiography-guided group (P = 0.63). Adverse events related to patent foramen ovale closure were low and did not differ between groups.

Conclusions

Our preliminary real-world experience suggests good efficacy and safety with intracardiac echocardiography and microprobe transoesophageal echocardiography guidance compared with conventional transoesophageal echocardiography guidance for percutaneous transcatheter patent foramen ovale closure in recurrent stroke prevention.